• Login
    View Item 
    •   DSpace Home
    • Araştırma Çıktıları | WoS | Scopus | TR-Dizin I PubMed
    • WoS İndeksli Yayınlar Koleksiyonu
    • View Item
    •   DSpace Home
    • Araştırma Çıktıları | WoS | Scopus | TR-Dizin I PubMed
    • WoS İndeksli Yayınlar Koleksiyonu
    • View Item
    JavaScript is disabled for your browser. Some features of this site may not work without it.

    Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus

    Thumbnail
    View/Open
    Mechanical properties and morphologic features of intrinsic foot muscles and plantar fascia in individuals with hallux valgus.pdf (651.3Kb)
    Date
    2019
    Author
    Tas, Serkan
    Çetin, Alp
    Metadata
    Show full item record
    Abstract
    Background: The aim of the present study was to investigate the morphologic features and mechanical properties of plantar fascia (PF), flexor hallucis brevis (FHB), flexor digitorum brevis (FDB), and abductor hallucis (AbH) muscles in individuals with halluks valgus (HV) and to compare the results with individuals without HV. Methods: A total of 30 participants (27 female, 3 male) between the ages of 19e58 years with HV deformity and 30 individuals without HV (27 female, 3 male) between the ages of 20e58 years were included in the study. AbH, PF, FHB, and FDB thickness, cross-sectional area and stiffness were measured with an ultrasonography device. For stiffness measurements, Shear Wave Velocity (SWV) of the assessed soft tissues was calculated using a customized software program. Results: Mean and standard deviation of SWV of PF, AbH, FHB, FDB, and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in individuals with HV were 7.6 ± 1.0 m/sec, 2.8 ± 0.3 m/sec, 2.6 ± 0.4 m/sec, and 3.4 ± 0.2 m/sec, 3.3 ± 0.5 mm, 11.4 ± 2.2 mm, 16.5 ± 1.9 mm, 8.9 ± 1.8 mm, 2.4 ± 0.5 cm2 , 2.7 ± 0.5 cm2 , 1.9 ± 0.6 cm2 , respectively. Mean and standard deviation of SWV of PF, AbH, FHB, FDB and thickness of PF, AbH, FHB, FDB, and cross-sectional area of AbH, FHB, FDB in controls groups were 7.6 ± 1.2 m/sec, 2.3 ± 0.3 m/sec, 2.3 ± 0.4 m/sec, and 3.4 ± 0.4 m/sec, 3.3 ± 0.5 mm, 9.7 ± 2.1 mm, 14.5 ± 1.4 mm, 9.7 ± 1.2 mm, 2.1 ± 0.3 cm2 , 2.3 ± 0.4 cm2 , 2.1 ± 0.4 cm2 , respectively. Individuals with HV had lower AbH and FHB thickness, cross-sectional area and SWV, however FDB thickness and crosssectional area were higher in individuals with HV compared to that of individuals without HV (p < 0.05). PF thickness (p ¼ 0.273), SWV of PF (p ¼ 0.979) and FDB (p ¼ 0.295) were similar in both groups. Conclusion: Our results suggest that individuals with HV had lower AbH and FHB stiffness, however PF and FDB stiffness were similar in HV and control group. In addition, AbH and FHB thickness and crosssectional area were lower in individuals with HV; however, FDB thickness and cross-sectional area were higher in individuals with HV compared to that of individuals without HV.
    URI
    http://acikerisim.toros.edu.tr/xmlui/handle/1/156
    Collections
    • PubMed İndeksli Yayın Koleksiyonu
    • WoS İndeksli Yayınlar Koleksiyonu

    DSpace software copyright © 2002-2022  LYRASIS
    Contact Us | Send Feedback
    Theme by 
    Atmire NV
     

     

    Browse

    All of DSpaceCommunities & CollectionsBy Issue DateAuthorsTitlesSubjectsThis CollectionBy Issue DateAuthorsTitlesSubjects

    My Account

    LoginRegister

    DSpace software copyright © 2002-2022  LYRASIS
    Contact Us | Send Feedback
    Theme by 
    Atmire NV